Nefit cv-ketel
Fault 2P: flow temperature rising too fast
The water in the boiler heats up faster than normal. That's due to too little flow: air, low pressure, closed valves or a faltering pump.
Do this first
- Check the water pressure and top up to 1.5 to 2 bar.
- Bleed all radiators.
- Open the radiator valves and reset the boiler.
When should you call an engineer?
If 2P keeps coming back, have an engineer check the pump and the heat exchanger.
Reset
Hold the reset button for a few seconds until the display shows 'rE' or 'reset'. If the code comes back, call an engineer.
Still under warranty?
Add your cv-ketel to your home file, with the installation date. Then you'll see whether it's still under warranty and get a reminder for servicing.
Add applianceFrequently asked questions
What does 2P mean on a Nefit cv-ketel?
The water in the boiler heats up faster than normal. That's due to too little flow: air, low pressure, closed valves or a faltering pump.
Can I fix 2P myself?
Check the water pressure and top up to 1.5 to 2 bar. Bleed all radiators. Open the radiator valves and reset the boiler. If 2P keeps coming back, have an engineer check the pump and the heat exchanger.