Vaillant cv-ketel
Fault F.75: no pressure difference when the pump starts
When the pump starts, the pressure sensor measures no change. Often there's air in the system or the pressure is too low; sometimes the pump or pressure sensor is broken.
Do this first
- Check the water pressure and top up to 1.5 to 2 bar.
- Bleed the radiators, starting on the lowest floor.
- Press reset once.
When should you call an engineer?
If F.75 comes back with the right pressure, an engineer has to replace the pump or the pressure sensor.
Reset
Press the reset button once (on most ecoTEC models the button with the arrows or 'reset'). If the boiler goes into fault again, don't keep resetting but call an engineer.
Still under warranty?
Add your cv-ketel to your home file, with the installation date. Then you'll see whether it's still under warranty and get a reminder for servicing.
Add applianceWant to know more? Read central heating boiler not working: what now?
Frequently asked questions
What does F.75 mean on a Vaillant cv-ketel?
When the pump starts, the pressure sensor measures no change. Often there's air in the system or the pressure is too low; sometimes the pump or pressure sensor is broken.
Can I fix F.75 myself?
Check the water pressure and top up to 1.5 to 2 bar. Bleed the radiators, starting on the lowest floor. Press reset once. If F.75 comes back with the right pressure, an engineer has to replace the pump or the pressure sensor.
Other Vaillant codes
- F.22 too little water in the boiler
- F.28 ignition failed
- F.29 flame goes out while burning
- F.20 overheating
- F.00 flow sensor interrupted
- F.01 return sensor interrupted
- F.10 flow sensor short circuit
- F.27 flame detected while the gas valve is closed
- F.61 fault in the gas valve control
- F.62 gas valve closes too slowly
- F.63 memory error (eeprom)
- F.64 fault in electronics or sensor
- F.73 pressure sensor signal too low
- F.83 dry firing at burner start
Checked in 11-2026. Codes can differ per model; if in doubt, check the manual of your appliance.