Vaillant error codes
What the codes on your Vaillant cv-ketel mean (ecoTEC plus, ecoTEC pure, ecoTEC exclusive, aroTHERM (hybride)), what you can safely do yourself and when you need an engineer.
Where do you see the code?
A fault shows on the display as F. with a number, for example F.28. A message without a dot (S. or a number) is a status, not a fault.
Reset
Press the reset button once (on most ecoTEC models the button with the arrows or 'reset'). If the boiler goes into fault again, don't keep resetting but call an engineer.
All codes
- F.27Flame detected while the gas valve is closedThe boiler sees a flame signal while no gas should be burning. That points to a fault in the gas valve or flame monitoring.Act immediately
- F.62Gas valve closes too slowlyThe flame stays visible too long after switching off. The gas valve doesn't close properly.Act immediately
- F.00Flow sensor interruptedThe temperature sensor in the flow gives no signal: the sensor, the plug or the cable is loose or broken.Engineer needed
- F.01Return sensor interruptedThe temperature sensor in the return gives no signal: the sensor, the plug or the cable is loose or broken.Engineer needed
- F.10Flow sensor short circuitThe flow sensor shows a short circuit. Sometimes due to moisture in the plug.Engineer needed
- F.20OverheatingThe safety thermostat has tripped: the water in the boiler got too hot. Often due to poor flow, air or a closed valve.Engineer needed
- F.28Ignition failedThe boiler tries to ignite but sees no flame. Often the gas tap is closed, the gas supply is disrupted or the igniter is dirty or broken.Engineer needed
- F.29Flame goes out while burningThe flame goes out while the boiler is working. Causes are an interrupted gas supply, a blocked condensate drain or flue, or a dirty burner.Engineer needed
- F.61Fault in the gas valve controlThe gas valve control isn't working properly: the gas valve or the circuit board is faulty.Engineer needed
- F.63Memory error (EEPROM)The boiler's electronics can't read its settings.Engineer needed
- F.64Fault in electronics or sensorThe electronics see an illogical value from a sensor, often due to a short circuit in a sensor or the circuit board.Engineer needed
- F.73Pressure sensor signal too lowThe signal from the water pressure sensor is too low: the sensor or the cable is faulty, or there's a short circuit.Engineer needed
- F.22Too little water in the boilerThe boiler detects too little water or too low a pressure and protects itself against boiling dry. Usually the water pressure is too low.Often fixable yourself
- F.75No pressure difference when the pump startsWhen the pump starts, the pressure sensor measures no change. Often there's air in the system or the pressure is too low; sometimes the pump or pressure sensor is broken.Often fixable yourself
- F.83Dry firing at burner startWhen the burner starts, the flow or return temperature changes too little. Usually too little water in the boiler, or air.Often fixable yourself
Questions about Vaillant
How do I reset my Vaillant cv-ketel?
Press the reset button once (on most ecoTEC models the button with the arrows or 'reset'). If the boiler goes into fault again, don't keep resetting but call an engineer.
Where is the fault code shown on my Vaillant?
A fault shows on the display as F. with a number, for example F.28. A message without a dot (S. or a number) is a status, not a fault.
Which Vaillant faults can I fix myself?
F.22 (too little water in the boiler), F.75 (no pressure difference when the pump starts), F.83 (dry firing at burner start): the page for each code lists the steps you can safely do yourself.
Other brands central heating boilers
Checked in 11-2026. Codes can differ per model; if in doubt, check the manual of your appliance.